Residence time inside the treatment and plumbing path.
Pet Shower Hygiene
Better Water for Better Pet Care.
Flow-based water treatment for pet shower and professional grooming wash stations.
- Better shower-water hygiene
- Flow-based WDS selection
- Lower cleaning burden
- Designed for pet shower water points

Size the Pet Shower water path.
Enter the shower demand you know. Unknown flow remains a preliminary recommendation.
10.0 LPMFlow per shower
×1Simultaneous showers
=10.0 LPM600 LPH
Preliminary concentration and contact assessment.
Concentration Performance
Concentration: PASS · CT: VALIDATION REQUIRED
Keep hydraulic time and pet-contact time separate.
Continuous treated-water application during the shower.
Reference CT ÷ predicted C; not a practical washing recommendation.
No practical minimum is fabricated.
Predicted C × entered pet-contact time.
Engineering validation required.
View Engineering Basis
- Selected WDS
- WDS1200X
- Ozone Output
- 120 mg/h
- Flow per Shower
- 10 LPM
- Simultaneous Showers
- 1
- Total Peak Flow
- 10.0 LPM · 600 LPH
- MTE
- 80% · verified
- MTE Source
- Verified Product Data
- Predicted C
- 0.160 mg/L
- Reference C
- 0.1 mg/L
- Reference Source
- BES configurable preliminary engineering reference · preliminary
- Hydraulic Contact Time
- Not known
- Pet Contact Time
- Not entered
- Achieved CT
- Pending
- Reference CT
- Not configured
Concentration formula: C = (120 mg/h × 80% MTE) ÷ 600 L/h.
CT formula: Achieved CT = predicted C × ozone-water pet contact time.
Missing engineering inputs: Ozone-water pet contact time, Reference CT
Assumption status: verified. Full disinfection PASS requires both concentration and applicable CT criteria to be valid and met.
EOG life follows actual shower-water runtime.
EOG Rated Life: 1,000 operating hours ÷ 30.0 water-flow hr/month. First EOG is included with the product.
Short checks, timed by real operating conditions.
Confirm the WDS and shower-water path operate normally.
Inspect according to actual site-water conditions.
Replace according to the selected product’s rated operating hours.
Recheck when flow, shower points, plumbing, or site conditions change.
Potential value without invented savings.
Detailed commercial analysis stays protected.
Public engineering results contain no protected commercial pricing.
Download the current engineering summary.

Public Engineering Summary
Includes selected product, flow, disinfection status, water runtime, EOG forecast, maintenance, assumptions, limitations, and BES contact. Public output contains no pricing.