BES PortalLogin / BES OS
BES APPLICATION · PET CARE

Pet Shower Hygiene

Better Water for Better Pet Care.

Flow-based water treatment for pet shower and professional grooming wash stations.

  • Better shower-water hygiene
  • Flow-based WDS selection
  • Lower cleaning burden
  • Designed for pet shower water points
Dog being washed with a visible handheld shower spray
Incoming WaterPre-FilterWDSPet Shower
Before WDSAfter WDS
Pet Shower Water Treatment
01 / APPLICATION INPUTS

Size the Pet Shower water path.

Enter the shower demand you know. Unknown flow remains a preliminary recommendation.

1. Number of shower points
2. Flow per shower point
BES Preliminary Flow Estimate

Preliminary Engineering Assumption · editable for the current estimate.

Flow used for sizing: 10 LPM · BES preliminary estimate.

TOTAL PEAK FLOW

10.0 LPMFlow per shower

×

1Simultaneous showers

=

10.0 LPM600 LPH

4. Estimated water-flow runtime

Water runtime means the total time water actually flows through the WDS, not business opening hours.

5. Product selection
03 / DISINFECTION PERFORMANCE

Preliminary concentration and contact assessment.

PRELIMINARY · ENGINEERING VALIDATION REQUIRED

Concentration Performance

Concentration: PASS · CT: VALIDATION REQUIRED

Dissolved Ozone Concentration vs Water FlowBlue curve · Predicted CGold line · Preliminary Engineering Reference
0.000.200.400.600.800510152025Reference C 0.10 mg/LCurrent 10.0 LPM · 0.160 mg/LWater Flow (LPM)Dissolved Ozone Concentration, C (mg/L)
0.160 mg/LPredicted C · PASS
0.10 mg/LPreliminary Engineering Reference · PRELIMINARY
PRELIMINARYOverall Disinfection Assessment
CT / CONTACT PERFORMANCE

Keep hydraulic time and pet-contact time separate.

Hydraulic Contact TimeNot entered

Residence time inside the treatment and plumbing path.

Continuous treated-water application during the shower.

Theoretical CT TimeReference CT unavailable

Reference CT ÷ predicted C; not a practical washing recommendation.

Practical Recommended Contact TimeBES Engineering Validation Required

No practical minimum is fabricated.

Achieved CTMore data required

Predicted C × entered pet-contact time.

Reference CT / StatusNot yet configured

Engineering validation required.

View Engineering Basis
Selected WDS
WDS1200X
Ozone Output
120 mg/h
Flow per Shower
10 LPM
Simultaneous Showers
1
Total Peak Flow
10.0 LPM · 600 LPH
MTE
80% · verified
MTE Source
Verified Product Data
Predicted C
0.160 mg/L
Reference C
0.1 mg/L
Reference Source
BES configurable preliminary engineering reference · preliminary
Hydraulic Contact Time
Not known
Pet Contact Time
Not entered
Achieved CT
Pending
Reference CT
Not configured

Concentration formula: C = (120 mg/h × 80% MTE) ÷ 600 L/h.

CT formula: Achieved CT = predicted C × ozone-water pet contact time.

Missing engineering inputs: Ozone-water pet contact time, Reference CT

Assumption status: verified. Full disinfection PASS requires both concentration and applicable CT criteria to be valid and met.

04 / WATER RUNTIME & EOG LIFE

EOG life follows actual shower-water runtime.

Estimated First EOG Replacement33.3 months

EOG Rated Life: 1,000 operating hours ÷ 30.0 water-flow hr/month. First EOG is included with the product.

Small / Occasional0.5 hr/day · 15.0 hr/month · 66.7 months
Typical1 hr/day · 30.0 hr/month · 33.3 months
Busy2 hr/day · 60.0 hr/month · 16.7 months
High Demand3 hr/day · 90.0 hr/month · 11.1 months
Selected Runtime1.00 hr/day · 30.0 hr/month · 33.3 months
05 / MAINTENANCE OVERVIEW

Short checks, timed by real operating conditions.

ROUTINEVisual check and normal operation

Confirm the WDS and shower-water path operate normally.

PERIODICPre-filter and water-path inspection

Inspect according to actual site-water conditions.

EOG REPLACEMENTAccumulated water runtime

Replace according to the selected product’s rated operating hours.

ENGINEERING REVIEWWhen conditions change

Recheck when flow, shower points, plumbing, or site conditions change.

06 / BUSINESS VALUE

Potential value without invented savings.

Lower Cleaning Burden
Odor Management Support
Operational Consistency
Better Pet Shower Water Hygiene
07 / CALCULATE ROI

Detailed commercial analysis stays protected.

Public engineering results contain no protected commercial pricing.

REPORT / BES ENGINEERING SUMMARY

Download the current engineering summary.

BES Group Thailand

Public Engineering Summary

Includes selected product, flow, disinfection status, water runtime, EOG forecast, maintenance, assumptions, limitations, and BES contact. Public output contains no pricing.

08 / NEXT STEP / CONTACT BES

Confirm the final Pet Shower design.

PET FAMILY / SEPARATE APPLICATIONS

Explore Pet Solutions